Cookie preferences
This website uses cookies, which are necessary for the technical operation of the website and are always set. Other cookies, which increase the comfort when using this website, are used for direct advertising or to facilitate interaction with other websites and social networks, are only set with your consent.
Configuration
Technically required
These cookies are necessary for the basic functions of the shop.
"Allow all cookies" cookie
"Decline all cookies" cookie
CSRF token
Cookie preferences
Currency change
Customer recognition
Customer-specific caching
Individual prices
Selected shop
Session
Comfort functions
These cookies are used to make the shopping experience even more appealing, for example for the recognition of the visitor.
Note
Show the facebook fanpage in the right blod sidebar
Statistics & Tracking
Affiliate program
Google Tag Manager
Track device being used
Safety module for elevator controls
LG 5925/034
- Article number: 0064797
- Type: LG5925.03/034 AC/DC24V
Bridging of the door and locking switches while moving the elevator in the unlocking zone with... more
Product description
Bridging of the door and locking switches while moving the elevator in the unlocking zone with open doors according to EN81-20/-50 for elevators for people and loads.
Technical specifications
Width: | 22,5 mm |
Cat. / PL acc. to EN ISO 13849-1: | 4/e |
SIL CL acc. to IEC/EN 62061: | 3 |
Nominal voltage: | AC/DC |
Thermal current Ith max.: | 5 A |
1- / 2-channel: | 1, 2 |
Cross fault detection: | Yes |
Connection: | Screw terminals, Pluggable screw terminals, Pluggable cage clamp terminals |
Output contacts max.: | 1 NC contact, 3 NO contacts |
Type: | LG 5925/034 |
Downloads
Advantages
- For elevators according to EN 81-20/-50
Features
- According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508
- Directive 2014/33/EU for elevators - Output: 3 NO contacts, 1 NC contact
- Single or 2-channel operation
- Line fault detection on On-button
- Manual restart or automatic restart, switch S2
- With or without cross fault monitoring in the loop, switch S1
- LED indicator for channel 1, 2 and supply voltage
- Degree of protection IP40; can be mounted in cabinets and installations with lower degree of protection without additional measures (depending on ambient conditions)
- Wire connection: also 2 x 1.5 mm2 stranded ferruled (isolated), DIN 46 228-1/-2/-3/-4 or 2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3
- As option with pluggable terminal blocks for easy exchange of devices
- With screw terminals
- Or with cage clamp terminals - Width 22.5 mm