Dold Industries Ltd

11 Hamberts Rd. Blackall Ind. Estate
South Woodham Ferrers
GB-Essex, CM3 5UW
LG 5928

Emergency stop module with time delay

LG 5928

Contacts

Nominal voltage

Time range

Terminal type

Approvals and Markings

Variant

  • 0061683
  • LG5928.41/61 DC24V 1-10S
Protection of people and machines Emergency stop circuits on machines, Stop category 1 can... more

Product description

  • Protection of people and machines
  • Emergency stop circuits on machines, Stop category 1 can be realised
  • Monitoring of safety gates

Technical specifications

Width: 22,5 mm
Cat. / PL acc. to EN ISO 13849-1: 4/e
SIL CL acc. to IEC/EN 62061: 3
Nominal voltage: DC
Suited as safety gate monitor: Yes
Thermal current Ith max.: 8 A
1- / 2-channel: 1, 2
Cross fault detection: Yes
Connection: Screw terminals, Pluggable screw terminals, Pluggable cage clamp terminals
Output contacts max.: 2 NO contacts, 1 NO contact delayed
Approvals: UL
Type: LG 5928

Advantages

  • Compact, flexible and safe
  • Short response time
  • Ideal for designs according to the new safety standards

Features

  • According to
    - Performance Level (PL) e and category 4 to EN ISO 13849-1
    - SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
    - Safety Integrity Level (SIL) 3 to IEC/EN 61508 and IEC/EN 61511
  • Output: 2 NO instantaneous contacts and 1 release delay contact
  • 1- or 2-channel connection
  • Line fault detection at the ON pushbuttons at connection on terminals S33-S34
  • Manual restart with button on S33-S34 or automatic restart with bridge between S13-S34
  • With or without cross fault monitoring in the E-stop loop
  • Indication for released time circuit
  • LED indication for supply, channel 1/2 and release delayed contacts
  • Wire connection: also 2 x 1.5 mm2 stranded ferruled (isolated), DIN 46228-1/-2/-3/-4 or 2 x 2.5 mm2 stranded ferruled DIN 46228-1/-2/-3
  • As option with pluggable terminal blocks for easy exchange of devices
    - with screw terminals
    - or with cage clamp terminals
  • Width 22.5 mm